Definitions
Download as PDF
Hazardous Area
Atmospheric condition | Areu00a0commonly referred to as ambient temperatures and pressures. That is to say temperatures of u201320u00b0C to 40u00b0C and pressures of 0.8 to 1.1 bar. |
DSEAR | The Dangerous Substances and Explosive Atmospheres Regulations 2002 |
Explosive Atmosphere | A mixture of dangerous substances with air, under atmospheric conditionis, in the form of gases, vapours, mist of dust in which, after ignition has occurred combustion spreads to the entire unburned mixture. |
Hazardous Area | Place where an explosive atmosphere may occur in quanitites that require special precautions to protect the health and safety of workers |
Non-Hazardous Area | A place where an explosive atmosphere is not expected to occur in quantities that require such special precautions |
Special Precautions | Precautions to control potential ignition sources within a hazardous area, particularly in relation to the construction, installation and use of equipment. |
Lighting Genenral
CFL | Compact Fluorescent Lamp Miniature u00adu2010 Compact fluorescent lamps, 9 to 55w |
Colour Appearance | The visual appearance of the colour of the light given out by the lamp. Usually described as Warm or cool etc. Often given as colour temperature. arm would be in the region of 3000 Kelvin, cool in the region of 4000 Kelvin Efficacy |
Efficacy | The ratio of light output, measured in lumens, to the amout of power used by the lamp to produce the light, including any power consumed by the control gear if used. Generally expressed in Lumens / Watts. |
GLS | General Lighting Service -u00adu2010 Simple Tungsten Lamps |
Kelvin | A temperature scale broadly similar to centigrade, but starting from absolute zero (-u00adu2010273 centigrade). Thus 1000 degrees C is equal to 1273 degrees Kelvin. |
Light Output | The amount of light measured in lumens that the lamp emits under normal conditions. Measured after 100 hours burning in case of dischage lighting. |
PAR Lamp | Parabolic Aluminised Reflector Lamps -u00adu2010 Tungsten Lamps in a heavy duty spot form |
Service Period | The average life in the case of tungsten lamps, or the number of hours after which discharge lamps should be changed as to give a resonable return of light for energy used. |
Lighting – Emergency
Anti Panic Lighting | The part of the emergency escape lighting provided to avoid panic and provide illumination to allow people to reach a place where an escape route can be found. |
Ballast Lumen Factor (BLF) | The ratio of the light output of the lamp when the ballast is operated at its design voltage compared with the output of the same lamp operated with the appropriate ballast supplied at its rated voltage and frequency. |
BS EN60598-u00adu20102-u00adu201022:1999 | This is British European luminaire product standard. |
BS5266 | The British Standard for emergency lighting, it has now been revised to conform with the European Standard EN1838. It is now issued in the UK under the reference BS EN 1838 / BS5266 Part 7. |
Central Battery System | A system where the batteries for a number of fittings are housed in one location, usually for all of the fittings in one sub-u00adu2010circuit. |
Central Test | A testing systems for a wide range of applications operating on 24v, 50v or 110v as well as Static Invertor projects. |
Combined Emergency Fitting (Sustained) | A light fitting containing two or more lamps at least one of which is energised from the emergency supply, the remaining lamps are supplied from the normal supply. |
Conversion Kit | A product used to provide standard mains luminaries -u00adu2010 including low voltage -u00adu2010 with an emergency back up should the mains power fail |
Emergency Exit | A way out intended to be used at any time. Final Exit is the terminal point of an escape route at which persons are no longer in danger from any hazard requiring evacuation of the building |
Escape Route Lighting | Provided to ensure the means of escape can be effectively identified and used |
Externally Illuminated Safety Sign | A sign that is illuminated when it is required by an external source. |
'F' Mark | Shows the luminaire can be mounted on flammable surfaces |
High Risk Area Lighting | The part of escape route lighting provided at a potentially dangerous location to enable proper shutdown procedures for the safety of the operator and other occupants of the building. |
Housing 850oC Test | All emergency luminaries on escape routes must pass this test. Selfu2010extinguishing grades of plastic must be used. |
ICEL 1001 | Registration is the industry standard of approval for photometric claimed data and performance of emergency lighting equipment which is tested by the BSI> |
ICEL 1004 | The industry standard and accepted practice for the conversion of mains luminaries to having an emergency battery powered back up. |
Internally Illuminated Safety Sign | A sign that is illuminated, when it is required by an internal source |
K Factor | The ratio between the light output from the lamp in the worst condition, normally at end of discharge and with cable volt drop, to the light output at nominal voltage. |
Maintained Emergency Lighting | A light fitting containing one or more lamps all of which operate from both he normal and emergency supply at all times. |
Mounting Height | The vertical distance between the light fitting and the floor |
Nonu2010maintained Emergency Lighting | A light fitting containing one or more lamps all of which operate from the emergency supply only following the failure of the mains supply. |
Normal Lighting | All permanently installed artificial lighting operating from the mains supply for use when inadequate lighting is available during occupation of the building. |
Rated Duration | The manufacturer's declared duration for a battery operated emergency light. Typically one to three hours when fully charged. |
Rated Load | The maximum load which may be connected to the system which will be supplied for the rated duration. |
Reu2010Charge Period | The time taken for the batteries to regain sufficient capacity to achieve their rated duration |
Safety Sign | A sign which gives a general safety message, obtained by a combination of colour and geometric shape and which by the addition of a graphic symbol or text, gives a particular safety message (ISO 3864: 1984 ) |
Self Contained Emergency Light Fitting | A fitting or sign providing maintained, non-u00adu2010maintained or combined emergency lighting in which all of the operating components are within 1 meter of the housing. |
Self Test | A testing system for a wide range of self contained luminaries |
Slave Fitting | An emergency light fitting without it's own batteries that is design to work within a central battery system |
Standby Lighting | That part of emergency lighting provided to enable normal activities to continue substantially unchanged (IEC 50 Chapter 845) |
Static Invertor | A central systems which enables mains luminaries to be utilised as emergency fittings without the need for additional wiring. |
Sustained Emergency Lighting | See combined emergency lighting |
Uniformity Ratio | The ratio between maximum to minimum illuminance measured at the working plane. |
Uninterruptible Power Supply (UPS) | A versatile method of providing back up power and or steady, constant mains supply to specific applications such as I.T. and telephones as well as being used to provide an emergency lighting facility in certain installations. |
Utilisation Factor At Zero Reflectance (U.F.O.) | Determines the proportion of light output from a lamp that falls directly on the floor for different room indexes and types of diffuser. |