Technical Resources

We have gathered together a number of technical resources for use as reference on electrical projects.

DISCLAIMER: The information on this page and the PDF is for information only and R&M Electrical Group Ltd can not be held liable for any information therein.

Cable: Cat6 Cable Specification

PDF Icon Download as PDF

Specification for Hyper-Data 2000
CAT6 UTP Stranded LSZH Lan Cable

Spec. No. S901106 Version: B Date: March 25th, 2008

TIA/EIA-568-B.2-1: Patch Cable (Stranded Conductor), 24 AWG x 4P

1. Conductor:Stranded Bare Copper (7 x 32 AWG)
2. Insulation:HDPE (CMI-75E)Nominal Wall Thickness: 0.178mm
Min. Thickness: 0.153mm
3. Color Code:Pair 1: Blue & White/Blue
Pair 2: Orange & White/Orange
Pair 3: Green & White/Green
Pair 4: Brown & White/Brown
4. Jacket (Grey):75°C LSZH Compound Nominal Wall Thickness: 0.585mm
Min. Thickness: 0.458mm
Overall Diameter: 5.8mm ± 0.3mm
5. Electric Requirements:(Cable length: 100m) Characteristic Impedance (Zo): 85~115Ω (1~250 MHz)
DC. Resistance Capacitance Unbalance: 5%
Pair-to-Ground Capacitance Unbalance: 330 pF/100m Max.
Conductor Resistance: 14.00Ω/100m 20o Max.
Mutual Capacitance: 5.6nF/m Max.
Spark Test: 2.5kV
Nominal Velocity of Propagation (NVP): 69%

RoHS Compliant

Frequency MHzAtt. StrandedPr-Pr NEXTPS NEXTProp. Delay nsDelay Skew nsReturn LossPr-Pr ELFEXTPS ELFEXT
12.474.372.3538.5452067.864.8
107.159.357.3545452547.844.8
2010.254.852.8539.9452541.838.8
31.2512.851.949.9540.24523.337.934.9
62.518.547.445.4540.84520.731.928.9
10023.844.342.3541.4451927.824.8
20034.839.837.8542.54516.421.818.8
25039.438.336.35434515.619.816.8

PDF Icon Download as PDF